TA-2.0 del analizador TOC

TA-2.0 del analizador TOC
TA-2.0 del analizador TOC
Descripción :
The MedIntegrity Automatic TA-2.O analyzer measures the amount of total carbon, inorganic carbon (IC) and total organic carbon (TOC) in water. The model TA-2.0 TOC Analyzer measures TOC using the UV oxidation method and this technique measures TOC based on the measurement of UV absorption in thesample. The MedIntegrity Automatic TA-2.0 model provide excellent TOC measurement accuracy and repeatability to ensure compliance with water quality standards.

TA-2.0 del analizador TOC Detalles

¿Qué es el Carbono Orgánico Total (COT)?
El carbono orgánico total es una medida de la cantidad de compuestos orgánicos contenidos en una muestra de agua. Los compuestos orgánicos que contienen carbono pueden disolverse en agua o existir en agua como material no disuelto, suspendido o líquido. Esta materia orgánica puede entrar en el agua de forma natural y a través de fuentes / procesos hechos por el hombre. Ejemplos de materia orgánica son sustancias a base vegetal o animal, o sintéticas que contienen carbono y otros elementos que definen compuestos orgánicos. La materia inorgánica es compuestos que contienen carbono mineral.

¿Por qué medir el TOC?
Mientras que la materia orgánica es’ t necesariamente tóxico, las altas concentraciones en el agua pueden afectar significativamente los ecosistemas y dañar el equipo cuando no se controlan y no se tratan. Los compuestos orgánicos pueden ser tóxicos para el medio ambiente en ríos o arroyos, incluso si los propios compuestos no son directamente tóxicos. Al agotar los niveles de oxígeno en el agua, los residuos orgánicos pueden conducir a la asfixia de los peces y pueden afectar a los ecosistemas acuáticos de muchas otras maneras.

MedIntegrity TA-2.0 Ensure Compliance with Regulations
The MedIntegrity Automatic TA-2.0 analyzer perform significantly better when low-level detection is needed. The reaction occurs at a much lower temperature than combustion (95-100 °C, compared to >680 °C in combustion), so a larger volume of sample can be injected intothe system without concern for rapid expansion. While in UV oxidation method, UV light is the heat source. As a result, turbid samples may reduce the intensity of the UV light that reaches the sample matrix, which would therefore reduce the oxidative capacity of the system.

TA-2.0 del analizador TOC Beneficios

En la industria farmacéutica, los sistemas TOC se utilizan en entornos de laboratorio regulados y, por lo tanto, estos sistemas están sujetos a diversas regulaciones que se aplican particularmente al software de instrumentos.
The MedIntegrity Automatic TA-2.0 analyzer software running andprovides full support for complying with the regulations, while still remaining extremely user-friendly. The software use is enabled via user access rights. It offers user accounts on four different levels, each protected through own passwords. The administrator can individually change access rightsfor each user. The software allows changing of login during ongoing operation. This is especially important for laboratories working under multiple shift operation.

Parámetros

Modelo TA-2.0
Método de medición Método de conductividad directa de oxidación UV
InstrumentoDimensiones 400 mm x 240 mm x 270 mm
Peso 8Kg (Neto)
Potencia primaria: AC100-240V 50-60Hz Humedad de funcionamiento: 25-60%
Temperatura de almacenamiento: 5-50 ° C Precisión: ± 3%
Registro de prueba electrónico: Sí Resolución: O.001mg/L
Tiempo de respuesta: < 4 minutos
Rango de medición: 0.001mg / L-1.5mg / L (1ppb – 1500ppb)
Rango de detección de conductividad: O.O55us / cm-8.000us / cm
Temperatura de la muestra: 1-95 ° C Historia: > 3 años
Reproducibilidad: ≤3% Ruta de auditoría: > 3 años
Garantías de integridad de datos: Control de usuario de 4 niveles que cumple con 21 CFR Parte 11
Diseño higiénico para uso en sala limpia:√ Opción de la impresora: √
Puertos de calibración fácilmente accesibles: √ Límite de detección: O.001mg/L
Estándares de calificación: GMP